15 configurations
Electrical switchgear: medium voltage, low voltage and ring main units
Low-voltage GCS/MNS boards, KYN28 metal-clad switchgear, ring main units and SF6 or solid-insulated cabinets from 400 V to 35 kV.

- Configurations
- 15
- Voltage class
- 1–35 kV
- Frequency
- 50 / 60 Hz
15 products
Products
-
Compact Ring Main Unit for 6.3kV, 10kV and 12kV Networks, 4000A Indoor Cabinet
- 4000 A
- 6.3–12 kV
- 50/60 Hz
-
Digital-Relay HV Switchgear Cabinet 12kV and 24kV, 4000A, Stainless IP65 Housing
- 4000 A
- 24 kV / 12 kV
- 50/60 Hz
-
Indoor HV Metal-Clad Switchgear 12kV 24kV 35kV, 4000A, Stainless Steel IP65
- 4000 A
- 12–35 kV
- 50/60 Hz
-
Intelligent Solid-Insulated SF6 Ring Network Cabinet 12-33kV, 630A to 2500A
- 630 A / 1600 A / 2500 A
- 33 kV
- 50/60 Hz
-
KYN28 Metal-Clad Main Switchboard 10kV to 33kV, 4000A, Stainless Steel IP65
- 4000 A
- 33 kV / 10 kV
- 50/60 Hz
-
KYN28A-12 Armoured Draw-Out Switchgear for 12kV Indoor Substations, 4000A
- 4000 A
- 12 kV
- 50/60 Hz
-
SF6 Gas-Insulated Medium Voltage Switch Cabinet 12kV 24kV 33kV, up to 2500A
- 630 A / 1600 A / 2500 A
- 12–33 kV
- 50/60 Hz
-
Sealed SF6 Ring Main Unit for 12kV and 24kV Ring Networks, 630A-2500A Indoor
- 630 A / 1600 A / 2500 A
- 24 kV / 12 kV
- 50/60 Hz
-
Smart KYN28A-12 Distribution Switchboard 12kV-35kV 4000A, Al-Zn Steel, IP65
- 4000 A
- 35 kV / 12 kV
- 50/60 Hz
No products match these filters
Remove a filter, or tell us what you need: most ratings can be built to order.
How to choose hv & lv switchgear
Switchgear protects and switches the circuits between the transformer and the loads. On the medium-voltage side the range covers withdrawable metal-clad panels such as KYN28 with vacuum circuit breakers, ring main units for looped cable networks, and SF6 gas-insulated or solid-insulated cabinets where space or environment is tight. On the low-voltage side, GCS and MNS draw-out boards and motor control centres distribute power to feeders and drives.
To quote accurately we need the single-line diagram, rated voltage and current, short-time withstand current and duration, internal arc classification, the protection relays and communication protocol, and the cable entry direction. MV assemblies are built to IEC 62271-200 and LV assemblies to IEC 61439.
Further reading
- What is electrical switchgear? Types, components and ratings
- Medium voltage switchgear: metal-clad, metal-enclosed and RMUs
- Ring main units: SF6 vs solid-insulated vs air-insulated
- Vacuum vs SF6 circuit breakers for medium voltage
- Gas-insulated vs air-insulated switchgear: GIS vs AIS compared
- Switchgear vs switchboard vs panelboard: the differences
HV & LV Switchgear: common questions
What is electrical switchgear?
Electrical switchgear is the assembly of switching and protection devices, such as circuit breakers, load-break switches, disconnectors, fuses, relays and instrument transformers, that controls, protects and isolates electrical equipment. Medium-voltage switchgear works above 1 kV; low-voltage switchgear and switchboards distribute power at 400 V to 690 V.
What is the difference between switchgear and a switchboard?
In North American usage, switchgear has draw-out power circuit breakers in separate compartments and is built and tested to a higher short-time withstand, while a switchboard uses fixed or plug-in moulded-case breakers in a lighter structure. Under IEC both are covered as assemblies: IEC 62271-200 for medium voltage and IEC 61439 for low voltage.
What is a ring main unit used for?
A ring main unit switches and protects a looped medium-voltage cable network. It lets the network operator isolate one cable section while the rest of the ring keeps supplying customers.
SF6 or solid-insulated switchgear?
SF6 gas-insulated switchgear is compact and proven, but SF6 is a potent greenhouse gas and new installations are being restricted in some markets, including the EU. Solid-insulated and clean-air designs avoid the gas. Tell us the destination so we can propose a compliant option.
What is internal arc classification?
IAC under IEC 62271-200 shows that a switchgear assembly has been tested to protect people at specified sides (front, lateral, rear) during an internal arc fault, for a stated current and duration.
Application examples using switchgear equipment
Vietnam50 Hz · Substation
United Arab Emirates50 Hz · Switchgear11 kV Switchgear Lineup for Commercial Buildings
Mexico60 Hz · Substation13.8 kV/480 V Compact Substation for an Automotive Components Factory
Send your single-line diagram. Get a technical proposal back.
Tell us the rating, voltages and site. Our engineers review it against your network before pricing, and reply with ratings, losses, dimensions, test scope and a quotation.
- kevin@toppower-asia.com
- WhatsApp / WeChat +86 186 1664 1467
- Room A09, Building 2, No. 619 Longchang Road, Yangpu District, Shanghai, China