Toppower Asia home

15 configurations

Electrical switchgear: medium voltage, low voltage and ring main units

Low-voltage GCS/MNS boards, KYN28 metal-clad switchgear, ring main units and SF6 or solid-insulated cabinets from 400 V to 35 kV.

800V 630A Withdrawable Low Voltage Distribution Panel with Al-Zn Coated Enclosure (product scene)
Configurations
15
Voltage class
1–35 kV
Frequency
50 / 60 Hz

15 products

Products

Compare products

How to choose hv & lv switchgear

Switchgear protects and switches the circuits between the transformer and the loads. On the medium-voltage side the range covers withdrawable metal-clad panels such as KYN28 with vacuum circuit breakers, ring main units for looped cable networks, and SF6 gas-insulated or solid-insulated cabinets where space or environment is tight. On the low-voltage side, GCS and MNS draw-out boards and motor control centres distribute power to feeders and drives.

To quote accurately we need the single-line diagram, rated voltage and current, short-time withstand current and duration, internal arc classification, the protection relays and communication protocol, and the cable entry direction. MV assemblies are built to IEC 62271-200 and LV assemblies to IEC 61439.

Further reading

HV & LV Switchgear: common questions

What is electrical switchgear?

Electrical switchgear is the assembly of switching and protection devices, such as circuit breakers, load-break switches, disconnectors, fuses, relays and instrument transformers, that controls, protects and isolates electrical equipment. Medium-voltage switchgear works above 1 kV; low-voltage switchgear and switchboards distribute power at 400 V to 690 V.

What is the difference between switchgear and a switchboard?

In North American usage, switchgear has draw-out power circuit breakers in separate compartments and is built and tested to a higher short-time withstand, while a switchboard uses fixed or plug-in moulded-case breakers in a lighter structure. Under IEC both are covered as assemblies: IEC 62271-200 for medium voltage and IEC 61439 for low voltage.

What is a ring main unit used for?

A ring main unit switches and protects a looped medium-voltage cable network. It lets the network operator isolate one cable section while the rest of the ring keeps supplying customers.

SF6 or solid-insulated switchgear?

SF6 gas-insulated switchgear is compact and proven, but SF6 is a potent greenhouse gas and new installations are being restricted in some markets, including the EU. Solid-insulated and clean-air designs avoid the gas. Tell us the destination so we can propose a compliant option.

What is internal arc classification?

IAC under IEC 62271-200 shows that a switchgear assembly has been tested to protect people at specified sides (front, lateral, rear) during an internal arc fault, for a stated current and duration.

Application examples using switchgear equipment

Send your single-line diagram. Get a technical proposal back.

Tell us the rating, voltages and site. Our engineers review it against your network before pricing, and reply with ratings, losses, dimensions, test scope and a quotation.

Rated power, voltages, frequency, standard, site conditions and destination port help us reply with a firm proposal.

Send via WhatsApp

Replies come from kevin@toppower-asia.com. Office hours are Monday to Friday, 9:00–18:00 China Standard Time.

Press Enter to see all matching products. Use ↑ ↓ to move through results.