23 configurations
Compact substations: box-type, prefabricated and mobile
Box-type, European-, American- and prefabricated substations from 6.3 kV to 36 kV and up to 5,000 kVA, built around one transformer, MV switching and an LV board in a single enclosure.

- Configurations
- 23
- Rating range
- 50 kVA – 5 MVA
- Voltage class
- 0.4–36 kV
- Frequency
- 50 / 60 Hz
23 products
Products
-
33 kV 630 kVA Outdoor Box-Type Distribution Substation, Three-Phase 50/60 Hz
- 630 kVA
- 33 kV
- 50/60 Hz
-
35 kV Three-Room Box Substation, Capacity 50-3150 kVA (200 kVA Typical)
- 50 kVA–3.15 MVA
- 35 kV
- 50/60 Hz
-
Chinese-Style Energy Storage PCS Step-Up Skid, 380 V to 10 kV or 15 kV
- 15 kV / 10 kV
- 50/60 Hz
-
Dry-Type or Oil-Type Transformer Box Substation, 1600 kVA, 12 kV to 0.4 kV
- 1.6 MVA
- 12 kV / 0.4 kV
- 50/60 Hz
-
Ethiopia EEU-Spec Box Substation, Dyn5 15/0.4 kV, 800 kVA Copper, IP65
- 800 kVA
- 0.4 kV
- 50 Hz
-
Heavy-Duty IP65 Substation, 4000 or 5000 kVA Oil Transformer, 25/35 kV 630 A
- 4–5 MVA
- 35 kV
- 50/60 Hz
-
IP65 Aluminium-Zinc Container Substation, IEC Switchgear, 33/35 kV 630 A
- 630 A
- 35 kV
- 50/60 Hz
-
Mobile Outdoor Container Substation Rated 3150 kVA, 6.3 kV to 0.8 kV, IP54
- 3.15 MVA
- 6.3 kV / 0.8 kV
- 50/60 Hz
-
Outdoor Prefabricated Box Substation 15 kV/0.4 kV, 200 kVA Three-Phase
- 200 kVA
- 15 kV / 0.4 kV
- 50/60 Hz
-
Relocatable Box Substation 600 kVA / 800 kVA, 25 kV to 400 V, Three-Phase
- 600–800 kVA
- 25 kV
- 50/60 Hz
-
Three-Compartment Outdoor Substation 1500 kVA at 33 kV, Arched Steel Roof
- 1.5 MVA
- 33 kV
- 50/60 Hz
-
Three-Phase 10 kV to 0.4 kV Outdoor Box Substation, 750 kVA or 1000 kVA
- 750 kVA–1 MVA
- 10 kV / 0.4 kV
- 50/60 Hz
-
Three-Phase 20 kV/0.4 kV Box Substation, 1250 kVA, Round-Coil Transformer
- 1.25 MVA
- 20 kV / 0.4 kV
- 50/60 Hz
-
Transportable 1600 kVA Container Box Substation, 10/0.4 kV, IP54 Enclosure
- 1.6 MVA
- 0.4 kV
- 50/60 Hz
No products match these filters
Remove a filter, or tell us what you need: most ratings can be built to order.
How to choose transformer substations
A box-type (compact or prefabricated) substation puts the MV switching, the distribution transformer and the LV board into one factory-assembled enclosure, so the site work shrinks to a foundation, cable entries and commissioning. The two main layouts are the European style, with separate compartments for MV, transformer and LV, and the American style, where the transformer tank itself carries the load-break switch and fuses.
Choose by network practice first, then by site. European-style units suit IEC networks and allow a dry-type or oil-immersed transformer inside; American-style units are lighter and smaller and fit loop-fed solar and residential feeders. Container substations add room for air-conditioning, auxiliary supplies and wider aisles where operators need to work inside.
Further reading
Transformer Substations: common questions
What is a compact substation?
A compact substation (also called a box-type, package or prefabricated substation) combines medium-voltage switchgear, a distribution transformer and a low-voltage board in one factory-assembled, type-tested enclosure. It arrives ready to set on a foundation and connect, which cuts site work and footprint compared with a built substation.
What is a mobile substation used for?
A mobile or relocatable substation is built on a skid, trailer or container frame so it can be moved between sites. It is used for temporary supply during construction or outages, for mines and oil fields that move, and as emergency backup while a permanent substation is repaired.
What is the difference between a European-style and an American-style box substation?
A European-style unit has three separate compartments (MV switchgear, transformer, LV distribution) in a steel or concrete housing. An American-style unit integrates the load-break switch and protection fuses into the transformer tank, which makes it more compact but less flexible for later changes.
Can a box substation use a dry-type transformer?
Yes. European-style and container substations can house either a cast-resin dry-type or an oil-immersed transformer. Dry-type units are chosen where fire risk or oil containment rules matter; oil-immersed units are usually lower in cost and losses for outdoor sites.
Which enclosure rating should I specify?
IP54 is common for outdoor box substations; dusty, coastal or desert sites often call for IP55 to IP65 and a heavier corrosion protection class. State altitude, ambient temperature range and salinity so ventilation and paint systems are sized correctly.
Application examples using substations equipment
Vietnam50 Hz · Substation
Philippines60 Hz · Energy storage13.8 kV Containerised Substation for an Island Microgrid
Mexico60 Hz · Substation13.8 kV/480 V Compact Substation for an Automotive Components Factory
Send your single-line diagram. Get a technical proposal back.
Tell us the rating, voltages and site. Our engineers review it against your network before pricing, and reply with ratings, losses, dimensions, test scope and a quotation.
- kevin@toppower-asia.com
- WhatsApp / WeChat +86 186 1664 1467
- Room A09, Building 2, No. 619 Longchang Road, Yangpu District, Shanghai, China