16 configurations
Power transformers for substations, from 1 MVA to 420 MVA
Oil-immersed power transformers from 1 MVA to 50 MVA and above, 66–230 kV class, with on-load tap changers for grid and generation substations.

- Configurations
- 16
- Rating range
- 1 MVA – 420 MVA
- Voltage class
- 10–230 kV
- Frequency
- 50 / 60 Hz
16 products
Products
-
110/115kV OLTC Power Transformer 20, 25 and 50 MVA with 11kV or 23kV Secondary
- 20–50 MVA
- 11–115 kV
- 50/60 Hz
-
110kV to 35kV Step-Down Power Transformer 15, 20 and 25 MVA, ONAN/ONAF Cooled
- 15–25 MVA
- 110 kV / 35 kV
- 50/60 Hz
-
40 MVA Copper-Wound PV Substation Transformer, 66kV to 15kV or 20kV, Oil-Immersed
- 40 MVA
- 15–66 kV
- 50/60 Hz
-
66kV to 415V Step-Down Transformer 2500 kVA, Three-Phase ONAN Oil-Immersed Unit
- 2.5 MVA
- 66 kV
- 50/60 Hz
-
66kV/22kV Three-Winding Substation Transformer Designed to IEC 60076, Oil-Filled
- 66 kV / 22 kV
- 50/60 Hz
-
EHV 220kV/230kV Power Transformer, 31500 to 420000 kVA, 35kV or 66kV Output
- 31.5–420 MVA
- 35–230 kV
- 50/60 Hz
-
Engineered-to-Order 25 MVA Oil Power Transformer, 66kV/69kV/72.5kV to 15kV
- 25 MVA
- 15–72.5 kV
- 50/60 Hz
-
Fully Sealed 20 MVA Power Transformer 110kV to 35kV with PCB-Free Mineral Oil
- 20 MVA
- 110 kV / 35 kV
- 50/60 Hz
-
High-Voltage 32, 40 and 50 MVA Transformer, 110kV/115kV Step-Down to 10.5kV
- 32–50 MVA
- 10.5–115 kV
- 50/60 Hz
-
Low-Loss 25 MVA and 30 MVA Power Transformer, 66kV or 110kV Primary, 23kV Output
- 25–30 MVA
- 23–110 kV
- 50/60 Hz
-
Oil-Field Duty Power Transformer 15 MVA or 20 MVA, 33kV/66kV to 10kV or 415V
- 15–20 MVA
- 10–66 kV
- 50/60 Hz
-
PV Step-Up Transformer 2 MVA, 15kV to 66kV, Three-Phase ONAN Oil-Immersed Design
- 2 MVA
- 66 kV / 15 kV
- 50/60 Hz
-
Solar Plant Grid-Tie Transformer 50 MVA, 110kV-230kV HV, 20kV/35kV/66kV LV
- 50 MVA
- 20–230 kV
- 50/60 Hz
-
Three-Phase Oil-Filled 110kV Substation Transformer, 1 MVA, 5 MVA and 16 MVA
- 1–16 MVA
- 110 kV
- 50/60 Hz
-
Three-Winding Oil-Immersed Transformer for 220kV and 66kV Transmission Substations
- 220 kV / 66 kV
- 50/60 Hz
-
Two-Winding 12500 kVA Oil-Immersed Transformer, 110kV Primary to 15kV Secondary
- 12.5 MVA
- 110 kV / 15 kV
- 50/60 Hz
No products match these filters
Remove a filter, or tell us what you need: most ratings can be built to order.
How to choose power transformers
Power transformers connect transmission and sub-transmission networks to distribution or generation. At these ratings each unit is engineered to the project: the voltage ratio, impedance, vector group, on-load tap changer range, cooling stages (ONAN/ONAF and above), noise limits and transport dimensions are agreed against the grid study and the route to site.
Send the single-line diagram, the network short-circuit level, the loss evaluation figures and any utility specification. Factory acceptance tests and witness inspection are planned with the order, and transport is usually arranged with radiators and bushings removed and the tank filled with dry gas or oil.
Further reading
Power Transformers: common questions
What is a substation transformer?
A substation transformer is the power transformer in a grid or industrial substation that steps transmission or sub-transmission voltage, such as 132 kV or 66 kV, down to a distribution voltage such as 33 kV or 11 kV. It is usually oil-immersed, fitted with an on-load tap changer and rated in MVA.
Can a power transformer be used as a step-up transformer?
Yes. The same construction is used as a generator step-up (GSU) unit at power plants and as the main step-up transformer at solar, wind and storage plants. The design is optimised for the direction of power flow, the vector group and the tap range the grid code requires.
Do I need an on-load tap changer?
Use an OLTC when the secondary voltage must stay within limits while the primary voltage or load changes, which is typical for grid substations and renewable plants. Off-circuit tap changers suit stable networks where taps are changed rarely.
How are power transformers shipped?
Large units are normally shipped with oil drained and the tank filled with dry nitrogen or dry air, with radiators, conservator and bushings packed separately and an impact recorder fitted. The oil is supplied in drums or by tanker for filling on site.
Can you supply three-winding transformers?
Yes. Three-winding units for 220/66 kV and 66/22 kV substations are in the range. The power split between windings and the impedances between each pair should be given in the enquiry.
Application examples using power equipment
Kenya50 Hz · Substation
Saudi Arabia60 Hz · Transformer33 kV/13.8 kV Solar Step-Up Transformer Bay
Egypt50 Hz · Transformer66 kV/11 kV Oil-Immersed Grid Transformer
Send your single-line diagram. Get a technical proposal back.
Tell us the rating, voltages and site. Our engineers review it against your network before pricing, and reply with ratings, losses, dimensions, test scope and a quotation.
- kevin@toppower-asia.com
- WhatsApp / WeChat +86 186 1664 1467
- Room A09, Building 2, No. 619 Longchang Road, Yangpu District, Shanghai, China