Power transformers for substations, from 1 MVA to 420 MVA

Oil-immersed power transformers from 1 MVA to 50 MVA and above, 66–230 kV class, with on-load tap changers for grid and generation substations.

110/115kV OLTC Power Transformer 20, 25 and 50 MVA with 11kV or 23kV Secondary (product scene)
Configurations
16
Rating range
1 MVA – 420 MVA
Voltage class
10–230 kV
Frequency
50 / 60 Hz

16 products

Products

Compare products

How to choose power transformers

Power transformers connect transmission and sub-transmission networks to distribution or generation. At these ratings each unit is engineered to the project: the voltage ratio, impedance, vector group, on-load tap changer range, cooling stages (ONAN/ONAF and above), noise limits and transport dimensions are agreed against the grid study and the route to site.

Send the single-line diagram, the network short-circuit level, the loss evaluation figures and any utility specification. Factory acceptance tests and witness inspection are planned with the order, and transport is usually arranged with radiators and bushings removed and the tank filled with dry gas or oil.

Further reading

Power Transformers: common questions

What is a substation transformer?

A substation transformer is the power transformer in a grid or industrial substation that steps transmission or sub-transmission voltage, such as 132 kV or 66 kV, down to a distribution voltage such as 33 kV or 11 kV. It is usually oil-immersed, fitted with an on-load tap changer and rated in MVA.

Can a power transformer be used as a step-up transformer?

Yes. The same construction is used as a generator step-up (GSU) unit at power plants and as the main step-up transformer at solar, wind and storage plants. The design is optimised for the direction of power flow, the vector group and the tap range the grid code requires.

Do I need an on-load tap changer?

Use an OLTC when the secondary voltage must stay within limits while the primary voltage or load changes, which is typical for grid substations and renewable plants. Off-circuit tap changers suit stable networks where taps are changed rarely.

How are power transformers shipped?

Large units are normally shipped with oil drained and the tank filled with dry nitrogen or dry air, with radiators, conservator and bushings packed separately and an impact recorder fitted. The oil is supplied in drums or by tanker for filling on site.

Can you supply three-winding transformers?

Yes. Three-winding units for 220/66 kV and 66/22 kV substations are in the range. The power split between windings and the impedances between each pair should be given in the enquiry.

Application examples using power equipment

Send your single-line diagram. Get a technical proposal back.

Tell us the rating, voltages and site. Our engineers review it against your network before pricing, and reply with ratings, losses, dimensions, test scope and a quotation.

Rated power, voltages, frequency, standard, site conditions and destination port help us reply with a firm proposal.

Send via WhatsApp