# Three-Phase Oil-Filled 110kV Substation Transformer, 1 MVA, 5 MVA and 16 MVA

Category: [Power Transformers](https://www.toppower-asia.com/products/power-transformer/)  
URL: https://www.toppower-asia.com/products/power-transformer/three-phase-oil-filled-110kv-substation-transformer-1/  
Supplier: Shanghai Toppower-Asia Co., Ltd. (Toppower Asia), Shanghai, China — kevin@toppower-asia.com, WhatsApp +86 186 1664 1467

Offered at 1, 5 or 16 MVA, this three-phase oil-immersed transformer takes a 110 kV supply down to 20 kV or 35 kV for substations and industrial networks. It is designed to IEC 60076 and combines a sealed tank, radiator cooling and a conservator for stable, efficient operation over many years.

## Key benefits

- **110 kV class in smaller ratings:** 1, 5 and 16 MVA options for compact substations.
- **Two LV choices:** 20 kV or 35 kV secondary voltage.
- **Reliable cooling:** sealed oil-immersed tank with radiators and conservator, ONAN or ONAF.
- **Common vector groups:** Dyn11 or Yyn0 for straightforward integration.
- **Low-loss windings:** copper or aluminium conductors selected for efficiency.

## Technical data

| Parameter | Specification |
| --- | --- |
| Product type | Three-phase oil-immersed power transformer |
| Rated capacity | 1 / 5 / 16 MVA |
| HV (input) voltage | 110 kV |
| LV (output) voltage | 20 / 35 kV |
| Frequency | 50 / 60 Hz |
| Phase | Three |
| Winding material | Copper / Aluminium |
| Vector group | Dyn11 / Yyn0 |
| Cooling | ONAN / ONAF (oil-immersed, radiator) |
| Design standard | IEC 60076 / GB |
| Certification | IEC 60076, ISO9001, ISO14001, CE, CQC documentation available on request (confirmed per order) |
| Selling unit | Single item |
| Packing | Wooden case |

## Construction & engineering

- Sealed steel tank carrying three porcelain HV bushings on the cover.
- Conservator mounted above the tank to take up oil expansion.
- Radiator banks fitted along the sides for heat dissipation.
- Cabinet for monitoring instruments and protective devices.
- Oil immersion keeps insulation stable and cooling efficient in substation and plant service.

## Typical applications

Utility and industrial substations, transmission and distribution networks, renewable-energy installations and large sites requiring 110 kV class transformation.

## Configuration options

Capacity, HV/LV voltages, vector group, tap changer arrangement, cooling class and fittings can be set to the project's single-line requirements.

## Information needed for a quotation

- Rated capacity (MVA or kVA) and number of units
- HV and LV rated voltages, tapping range and type of tap changer
- Frequency (50 Hz or 60 Hz) and vector group
- Preferred winding material (copper or aluminium) and cooling class
- Applicable design standard and any loss or impedance targets
- Site conditions: altitude, ambient temperature range, indoor/outdoor, seismic or pollution level
- Destination port and any transport size or weight limits

Request a quotation: https://www.toppower-asia.com/contact/

> Values shown are indicative only; final specification, dimensions and packing are fixed in the confirmed order.