# 6.6kV to 415V Low-Loss Three-Phase Oil Distribution Transformer, 1000kVA, IEC Design

Category: [Oil-Immersed Transformers](https://www.toppower-asia.com/products/oil-immersed-transformer/)  
URL: https://www.toppower-asia.com/products/oil-immersed-transformer/6-6kv-to-415v-low-loss-three-phase-oil-distribution/  
Supplier: Shanghai Toppower-Asia Co., Ltd. (Toppower Asia), Shanghai, China — kevin@toppower-asia.com, WhatsApp +86 186 1664 1467

This 1000 kVA low-loss oil distribution transformer reduces 6.6 kV to 415 V and is designed to IEC standards. It is part of a range spanning 15 kVA to 31500 kVA, and copper or aluminium windings are available with construction following IEC and GB.

## Key benefits

- **Low-loss performance:** reduced no-load loss and a low operating temperature.
- **6.6 kV primary:** suited to industrial and older urban MV systems.
- **Sealed corrugated tank:** no breathing, no oil top-up, minimal upkeep.
- **Service life:** designed for 20–30 years in outdoor duty.
- **Configurable:** vector group and windings chosen per project.

## Technical data

| Parameter | Specification |
| --- | --- |
| Type | Three-phase oil-immersed distribution transformer |
| Rated power | 1000 kVA |
| Family range | 15 kVA – 31500 kVA |
| Primary voltage | 6.6 kV |
| Secondary voltage | 415 V |
| Frequency | 50 / 60 Hz |
| Phases | Three |
| Conductor | Copper / Aluminium |
| Construction | Fully sealed |
| Vector group | Dyn11 / Yyn0 / Yd11 / YNd11 / Dyn5 |
| Expected service life | 20–30 years |
| Design standard | IEC / GB |
| Certification | IEC, CE, ISO9001, ISO14001, ISO45001, CQC, GOST, EAC documentation available on request (confirmed per order) |
| Supply unit | Single item |
| Packing | Wooden case |
| Packed dimensions | 280 × 200 × 250 cm |
| Gross weight | 5400 kg |

## Construction & engineering

The core and coils sit inside a hermetically sealed steel tank whose corrugated walls double as the cooling surface, so heat leaves the oil without the oil ever meeting the atmosphere. Because no outside air is drawn in, moisture pick-up and oil ageing are held back and no breather is required. High-voltage porcelain bushings and the low-voltage terminals are arranged on the tank cover, and a pressure-relief device together with oil-level protection safeguards the unit in service.

## Typical applications

- Utility distribution substations, indoor or outdoor
- Industrial and process plants
- Mines and oil-field power systems
- Commercial buildings and complexes
- Rural electrification networks

## Configuration options

- **Electrical:** capacity, voltage ratio and vector group to suit the network
- **Windings:** copper or aluminium conductor
- **Regulation:** off-load or on-load tap changer
- **Terminations:** bushing configuration matched to the installation

## Information needed for a quotation

- Rated power and number of units
- HV and LV voltages and the vector group
- Operating frequency (50 or 60 Hz)
- Copper or aluminium windings; off-load or on-load tap changer
- Applicable standard and any loss requirements from the tender
- Site conditions such as altitude, ambient temperature and pollution level
- Delivery destination (port or site) and required delivery date

Request a quotation: https://www.toppower-asia.com/contact/

> Values on this page are given for reference; the final specification, dimensions and packing are fixed in the technical agreement for each order.