# Cast-resin dry-type transformers

Cast-resin transformers from 30 kVA to 5,000 kVA at 6.3–35 kV, Class F/H insulation, for indoor sites where oil is not acceptable.

Dry-type transformers encapsulate the high-voltage windings in epoxy resin, so there is no liquid to leak or burn. That makes them the default for indoor substations in hospitals, data centres, high-rise buildings, tunnels, ships and industrial plants where fire safety and cleanliness rule out oil.

Key choices are the insulation class (F or H) and allowed temperature rise, cooling (AN natural air, or AF with fans for extra temporary capacity), enclosure protection (IP00 open core, IP20 or IP23 housings) and the environmental, climatic and fire behaviour classes of IEC 60076-11. A digital temperature controller with PT100 sensors normally comes with the unit.

## Configurations
- [100-500kVA Three-Phase Dry Isolation Transformer for 220V, 380V and 11kV Systems](https://www.toppower-asia.com/products/dry-type-transformer/100-500kva-three-phase-dry-isolation-transformer/)
- [1000kVA and 2000kVA Epoxy Resin Dry Power Transformer, 20kV to 0.4kV Three Phase](https://www.toppower-asia.com/products/dry-type-transformer/1000kva-and-2000kva-epoxy-resin-dry-power-transformer/)
- [22kV to 415V 1600kVA Epoxy Cast Resin Dry Transformer for Indoor Distribution](https://www.toppower-asia.com/products/dry-type-transformer/22kv-to-415v-1600kva-epoxy-cast-resin-dry-transformer/)
- [2500kVA 6.3kV/400V Three-Phase Resin-Encapsulated Dry-Type Power Transformer](https://www.toppower-asia.com/products/dry-type-transformer/2500kva-6-3kv-400v-three-phase-resin-encapsulated-dry/)
- [500kVA 10kV/380V Dry-Type Transformer for Electronics and Industrial Power Supply](https://www.toppower-asia.com/products/dry-type-transformer/500kva-10kv-380v-dry-type-transformer-for-electronics/)
- [500kVA 20kV to 415V Step-Down Cast Resin Dry Transformer, Three Phase](https://www.toppower-asia.com/products/dry-type-transformer/500kva-20kv-to-415v-step-down-cast-resin-dry-transformer/)
- [630kVA 20kV/0.4kV Copper-Wound Cast Resin Dry-Type Distribution Transformer](https://www.toppower-asia.com/products/dry-type-transformer/630kva-20kv-0-4kv-copper-wound-cast-resin-dry-type/)
- [Cast Resin Dry Transformer 100kVA to 2500kVA, 11kV or 13.8kV to 380V, 3-Phase](https://www.toppower-asia.com/products/dry-type-transformer/cast-resin-dry-transformer-100kva-to-2500kva-11kv-or-13/)
- [Compact 100/200/315kVA 10kV to 400V Three-Phase Cast Resin Dry Transformer](https://www.toppower-asia.com/products/dry-type-transformer/compact-100-200-315kva-10kv-to-400v-three-phase-cast/)
- [Enclosed 630kVA 15kV/380V Epoxy Cast Dry Power Transformer with Copper Coils](https://www.toppower-asia.com/products/dry-type-transformer/enclosed-630kva-15kv-380v-epoxy-cast-dry-power/)
- [Fire-Resistant Dry Step-Down Transformer 250-1250kVA, 10/11/13.8kV to 400V](https://www.toppower-asia.com/products/dry-type-transformer/fire-resistant-dry-step-down-transformer-250-1250kva-10/)
- [Indoor HV Dry-Type Transformer 630kVA, 15kV to 400V, Metal-Enclosed Three Phase](https://www.toppower-asia.com/products/dry-type-transformer/indoor-hv-dry-type-transformer-630kva-15kv-to-400v-metal/)
- [Low-Frequency Dry Isolation Transformer 30-5000kVA, 240/400V Input, 480/380V Output](https://www.toppower-asia.com/products/dry-type-transformer/low-frequency-dry-isolation-transformer-30-5000kva-240/)
- [Multi-Voltage 11kV, 15kV or 22kV Resin-Cast Dry Transformer, 200-400kVA to 400V](https://www.toppower-asia.com/products/dry-type-transformer/multi-voltage-11kv-15kv-or-22kv-resin-cast-dry/)
- [Quiet-Running Smart Dry Distribution Transformer 30-5000kVA, 6.6-35kV to 400V](https://www.toppower-asia.com/products/dry-type-transformer/quiet-running-smart-dry-distribution-transformer-30/)
- [Toroidal-Coil Low-Noise Resin Dry Transformer 30-5000kVA for Indoor Power Supply](https://www.toppower-asia.com/products/dry-type-transformer/toroidal-coil-low-noise-resin-dry-transformer-30-5000kva/)

## FAQ
### When is a dry-type transformer better than an oil-immersed one?
Choose dry-type for indoor or occupied spaces, sites with strict fire codes, or places where oil containment is impractical. For outdoor sites with no such constraints, oil-immersed units are usually lower in cost and losses.

### What does AF cooling add?
Forced-air fans let a dry-type transformer carry more than its natural-air rating for a period, which is useful for peaks and emergencies. Continuous rating should still be chosen on AN cooling.

### What enclosure rating do I need?
IP00 suits a locked electrical room with its own protection. IP20 or IP23 enclosures protect people and the unit from contact and dripping water. Higher ratings reduce cooling and must be checked against the losses.